ART-R SERIES INSTL_REVD - 1 -
Important Safety Instructions (save this instructions)
! WARNING: When using Art Screen R series, basic precautions should always be followed, including:
• Read the entire users manuals before attempting to use Art Screen R series.
• Keep everything and everyone away from Art Screen while in motion. Do not contact moving parts.
• The user must observe the Art Screen R series while TV Plasma is in motion at all times until it is stopped by pressing on one of the
directional arrows on the remote control.
• Follow the installation instructions provided to correctly install Art Screen R series. To prevent injury, Art Screen R series must be
snugly attached to the wall in accordance with the installation instructions.
• Art Screen R series restricts movement based upon the TV width set on the side controls located on the right of main shell. The TV
width must be set correctly before operating Art Screen R series.
• The Art Screen R series mounting set up is intended for use only with the maximum weight of 180 pounds (81 kg). Use with
TVs heavier than 180 pounds (81 kg) may result in instability and cause injury.
• To reduce the risk of injury, close supervision is necessary when an appliance is used near children.
• Only use attachments recommended or sold by the manufacturer.
• Do not use outdoors.
• To disconnect, turn all controls to the off (“O”) position, then remove plug from outlet.
• Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
• Unplug from outlet when not in use and before servicing or cleaning.
• Do not operate any appliance with a damaged cord or plug, or after the appliance malfunctions or is dropped or damaged in any
manner. Return appliance to the nearest authorized service facility for examination, repair, or electrical or mechanical adjustment.
• Connect to a properly grounded outlet only. See Grounding Instructions.
Grounding Instructions
This appliance must be grounded. In the event of malfunction or breakdown, grounding provides a path of least resistance for electric
current to reduce the risk of electric shock.
A quad outlet AC box is provided with this appliance for 120VAC connection. Connect 120VAC to this box to power the TV, X-Arm
and the IR remote control.
DANGER – Improper connection of the equipment-grounding conductor can result in a risk of electric shock.
This appliance is for use on a circuit having a nominal rating more than 120 V, 15 A and is for use on a circuit having a nominal rating
of 120 V), and is factory equipped with a specific electric cord and plug. No adapter should be used with this appliance. If the appliance
must be reconnected for use on a different type of electric circuit, the reconnection should be made by qualified service personnel; and
after the reconnection, the appliance should comply with all local codes and ordinances.
Vista de pagina 0
1 2 3 4 5 6 ... 11 12

Indice de contenidos

Pagina 1

ART-R SERIES INSTL_REVD - 1 - Important Safety Instructions (save this instructions) ! WARNING: When using Art Screen R series, basic pr

Pagina 2

ART-R SERIES INSTL_REVD - 10 - ART ROLLER INSTALLATION Vutec has made a significant improvement to control and reduce the vibration noise

Pagina 3

ART-R SERIES INSTL_REVD - 11 - Electrical Schematic Figure G Electrical Schematic

Pagina 4

ART-R SERIES INSTL_REVD - 12 - Troubleshooting: If there is no power to Art Screen, 1 - Check that X-Arm home position limit switch LS2

Pagina 5

ART-R SERIES INSTL_REVD - 2 - INSTALLATION INSTRUCTIONS (rev A) Recessed Mount Motorized Plasma Installation The Plasma must be retracte

Pagina 6 - Motor Limit Switches

ART-R SERIES INSTL_REVD - 3 - **See Instruction sheet provided with kits for details Fig

Pagina 7 - Dimensional Information

ART-R SERIES INSTL_REVD - 4 - Press the Power to ON (1) on X-Arm Control Box on side of Main Shell (See Figure 2). Manually keep Art rolled

Pagina 8

ART-R SERIES INSTL_REVD - 5 - Wood Frame Installation A typical wood frame including the liner is approximately 5-1/2 inches wide to proper

Pagina 9 - Figure A

ART-R SERIES INSTL_REVD - 6 - Open and Close Limits Setting The Open limit switch has been properly set for correct stop position. It shoul

Pagina 10 - Figure F

ART-R SERIES INSTL_REVD - 7 - Dimensional Information: Figure 15 Dimensional Information

Pagina 11 - Electrical Schematic

ART-R SERIES INSTL_REVD - 8 - Accessories Included Description QTY. Frame Assembly including Artwork and Motor 1 X-Arm 1 Wood Fra

Pagina 12 - Figure G

ART-R SERIES INSTL_REVD - 9 - WOOD FRAME INSTALLATION & REMOVAL Note: Do not pull the wood frame straight out. The c